Type designation |
SG30CX |
Input (DC) | |
Recommended max. PV input power |
45 kW |
Max. PV input voltage |
1100 V ** |
Min. PV input voltage / Start-up input voltage |
200 V / 250 V |
Rated PV input voltage |
585V |
MPP voltage range |
200 – 1000 V |
No. of independent MPP inputs |
3 |
No. of PV strings per MPPT |
2 |
Max. PV input current |
78 A (26 A / 26 A / 26 A) |
Max. DC short-circuit current |
120 A (40 A / 40 A / 40 A) |
Output (AC) | |
Max. AC Output power |
29.9 kVA |
Rated AC output apparent power |
29.9 kVA |
Max. AC output current |
48.15 A |
Rated AC voltage |
3 / N / PE, 230 / 400 V |
AC voltage range |
312 – 528 V |
Rated grid frequency / Grid frequency range |
50 Hz / 45 – 55 Hz, 60 Hz / 55 – 65 Hz |
Harmonic (THD) |
< 3 % (at rated power) |
Power factor at rated power / Adjustable power factor |
> 0.99 / 0.8 leading – 0.8 lagging |
Feed-in phases / connection phases |
3 / 3-PE |
Efficiency | |
Max. efficiency / European efficiency |
98.6 % / 98.3 % |
Protection | |
DC reverse polarity protection |
Yes |
AC short circuit protection |
Yes |
Leakage current protection |
Yes |
Grid monitoring |
Yes |
Ground fault monitoring |
Yes |
DC switch |
Yes |
AC switch |
No |
PV string monitoring |
Yes |
Q at night function |
Yes |
PID recovery function |
Yes |
DC Terminal Protective Cover |
Yes |
Communication dongle (EyeM4) |
Yes |
Surge Protection |
DC Type II / AC Type II |
General Data | |
Dimensions (W*H*D) |
702 * 595 * 310 mm |
Weight |
50 kg |
Topology |
Transformerless |
Degree of protection |
IP66 |
Night power consumption |
≤2 W |
Operating ambient temperature range |
-30 to 60 ℃ (> 45 ℃ derating) |
Allowable relative humidity range |
0 – 100 % |
Cooling method |
Smart forced air cooling |
Max. operating altitude |
4000 m (> 3000 m derating) |
Display |
LED, Bluetooth+APP |
Communication |
RS485 / WLAN / Optional: Ethernet |
DC connection type |
MC4 (Max. 6 mm²) |
AC connection type |
OT or DT terminal (Max.70 mm²) |
Compliance |
IEC 62109, IEC 61727, IEC 62116, IEC 60068, IEC 61683, IEC 61000-6-3, AS/NZS
4777.2:2020 |
Grid Support | Q at night function, LVRT, HVRT,active & reactive power control and power
ramp rate control |
Country of manufacture | China |
*: Only compatible with Sungrow Logger, EyeM4 and iSolarCloud
**: The inverter enters the standby state when the input voltage ranges between 1,000V and 1,100V. If the maximum DC voltage in the system can exceed 1000V, the MC4 connectors included in the scope of delivery must not be used. In this case MC4 Evo2 connectors must be used.
Đánh giá