Type designation |
SG3.0RS |
SG3.6RS | SG4.0RS | SG5.0RS |
SG6.0RS |
||
Input (DC) | |||||||
Recommended max. PV input power |
4.5 kWp | 5.4 kWp | 6 kWp | 7.5 kWp |
9 kWp |
||
Max. PV input voltage |
600 V |
||||||
Min. operating PV voltage / Start-up input voltage |
40 V / 50 V |
||||||
Rated PV input voltage |
360 V |
||||||
MPP voltage range |
40 – 560 V |
||||||
No. of independent MPP inputs |
2 |
||||||
Default No. of PV strings per MPPT |
1 |
||||||
Max. PV input current |
32 A (16 A / 16 A) |
||||||
Max. DC short-circuit current |
40 A (20 A / 20 A) |
||||||
Output (AC) | |||||||
Rated AC output power |
3000 W |
3680 W | 4000 W | 5000 W* |
6000 W |
||
Max. AC Output power |
3000 VA |
3680 VA | 4000 VA | 5000 VA* |
6000 VA |
||
Rated AC output current (at 230 V) |
13.1 A |
16 A | 17.4 A | 21.8 A** |
26.1 A |
||
Max. AC output current |
13.7 A |
16 A | 18.2 A | 22.8 A** |
27.3 A |
||
Rated AC voltage |
220 / 230 / 240 V |
||||||
AC voltage range |
154 – 276 V |
||||||
Rated grid frequency / Grid frequency range |
50 Hz / 45 – 55 Hz, 60 Hz / 55 – 65 Hz |
||||||
Harmonic (THD) |
< 3 % (at rated power) |
||||||
Power factor at rated power / Adjustable power factor |
> 0.99 / 0.8 leading – 0.8 lagging |
||||||
Feed-in phases / Connection phases |
1 / 1 |
||||||
Efficiency | |||||||
Max. efficiency |
97.9 % |
||||||
European efficiency |
97.0 % |
97.0 % | 97.2 % | 97.3 % |
97.5 % |
||
Protection | |||||||
Grid monitoring |
Yes |
||||||
DC reverse polarity protection |
Yes |
||||||
AC short-circuit protection |
Yes |
||||||
Leakage current protection |
Yes |
||||||
Surge Protection |
DC type II / AC type II |
||||||
DC switch |
Yes |
||||||
PV string current monitoring |
Yes |
||||||
Arc fault circuit interrupter (AFCI) |
Optional |
||||||
PID recovery function |
Yes |
||||||
General Data | |||||||
Dimensions (W*H*D) |
410 * 270* 150 mm |
||||||
Weight |
10 kg |
||||||
Mounting method |
Wall-mounting bracket |
||||||
Topology |
Transformerless |
||||||
Degree of protection |
IP65 |
||||||
Operating ambient temperature range |
-25 to 60 ℃ |
||||||
Allowable relative humidity range (non-condensing) |
0 – 100 % |
||||||
Cooling method |
Natural cooling |
||||||
Max. operating altitude |
4000 m |
||||||
Display |
LED digital display & LED indicator |
||||||
Communication |
Ethernet / WLAN / RS485 / DI (Ripple control & DRM) |
||||||
DC connection type |
MC4 (Max. 6 mm²) |
||||||
AC connection type |
Plug and play connector (Max. 6 mm²) |
||||||
Grid compliance |
IEC/EN62109-1/2, IEC/EN62116, IEC/EN61727, IEC/EN61000-6-2/3, EN50549-1, AS4777.2, ABNT NBR 16149, ABNT NBR 16150, UNE 217002:2020, NTS V2 TypeA,
CEI 0-21:2019, VDE0126-1-1/A1 (VFR-2019), UTE C15-712, C10/11, G98/G99 |
||||||
Grid Support | Active & reactive power control and power ramp rate control |
*: AS 4777.2: 4999W, 4999VA
**: AS 4777.2 :Rated and Max. AC current is 21.7A
Đánh giá