Type designation |
SG33CX |
SG40CX | SG50CX |
Input (DC) |
|
||
Max. PV input voltage |
1100 V ** |
||
Min. PV input voltage / Start-up input voltage |
200 V / 250 V |
||
Nominal PV input voltage |
585 V |
||
MPP voltage range |
200 – 1000 V |
||
No. of independent MPP inputs |
3 |
4 | 5 |
No. of PV strings per MPPT |
2 |
||
Max. PV input current |
3 * 26 A |
4 * 26 A |
5 * 26 A |
Max. DC short-circuit current |
3 * 40 A |
4 * 40 A |
5 * 40 A |
Output (AC) | |||
AC output power |
33 kVA @45 ℃, 400Vac / 36.3 kVA @ 40 ℃, 400Vac 33 KVA @ 50 ℃, 415Vac / 36.3 KVA @ 45 ℃, 415Vac |
40 kVA @ 45 ℃, 400Vac /
44 kVA @ 40 ℃, 400Vac 40 KVA @ 50 ℃, 415Vac / 44 KVA @ 45 ℃, 415Vac |
50 kVA @45 ℃, 400Vac / 55kVA @ 40 ℃, 400Vac 50KVA @ 50 ℃, 415Vac / 55kVA @ 45 ℃,415Vac |
Max. AC output current |
55.2 A |
66.9 A |
83.6 A |
Nominal AC voltage |
3 / N / PE, 230 / 400 V |
||
AC voltage range |
312 – 528 V |
||
Nominal grid frequency / Grid frequency range |
50 Hz / 45 – 55 Hz, 60 Hz / 55 – 65 Hz |
||
Harmonic (THD) |
< 3 % (at nominal power) |
||
DC current injection |
< 0.5 % In |
||
Power factor at nominal power / Adjustable power factor |
> 0.99 / 0.8 leading – 0.8 lagging |
||
Feed-in phases / AC connection |
3 / 3 |
||
Efficiency | |||
Max. efficiency / European efficiency |
98.6 % / 98.3 % |
98.6% / 98.3% |
98.7% / 98.4% |
Protection and Function | |||
DC reverse polarity protection |
Yes |
||
AC short circuit protection |
Yes |
||
Leakage current protection |
Yes |
||
Grid monitoring |
Yes |
||
Ground fault monitoring |
Yes |
||
DC switch |
Yes |
||
AC switch |
No |
||
PV string monitoring |
Yes |
||
Q at night function |
Yes |
||
PID recovery function |
Yes |
||
Arc fault circuit interrupter (AFCI) |
Optional |
||
Overvoltage protection |
DC Type II (optional: Type I + II) / AC Type II |
||
General Data | |||
Dimensions (W*H*D) |
702*595*310mm |
782*645*310mm |
782*645*310mm |
Weight |
50 kg |
58 kg |
62 kg |
Topology |
Transformerless |
||
Degree of protection |
IP66 |
||
Night power consumption |
≤2 W |
||
Operating ambient temperature range |
-30 to 60 ℃ (> 45 ℃ derating) |
||
Allowable relative humidity range |
0 – 100 % |
||
Cooling method |
Smart forced air cooling |
||
Max. operating altitude |
4000 m (> 3000 m derating) |
||
Display |
LED, Bluetooth+APP |
||
Communication |
RS485 / Optional: WLAN, Ethernet |
||
DC connection type |
MC4 (Max. 6 mm²) |
||
AC connection type |
OT or DT terminal (Max.70 mm²) |
||
Compliance | IEC 62109, IEC 61727, IEC 62116, IEC 60068, IEC 61683, VDE-AR-N
4105:2018, VDE-AR-N 4110:2018, IEC 61000-6-3, EN 50549-1/2, AS/NZS 4777.2:2015, CEI 0-21 2019, CEI0-16 2019, VDE 0126-1-1/A1 VFR 2019, UTE C15-712-1:2013, DEWA, UNE 206007-1/RD 1699, UNE 217001, Israel certificate, G99 |
||
Grid Support | Q at night function, LVRT, HVRT,active & reactive power control and
power ramp rate control |
*: Only compatible with Sungrow logger, EyeM4 and iSolarCloud
**: The inverter enters the standby state when the input voltage ranges between 1,000 V and 1,100 V. If the maximum DC voltage in the system can exceed 1000 V, the MC4 connectors included in the scope of delivery must not be used. In this case MC4 Evo2 connectors must be used.